What does a tall steel shop building look like in Indiana? This one is a 1,792 sq ft cold-formed steel shop building in Amo, Indiana, 32 ft wide, 56 ft long and 17 ft to the eave, with two 12 x 12 ft overhead doors, engineered to the 2012 International Building Code for 115 mph winds (Exposure C) and a 20 psf ground snow load. Toro designed, engineered and supplied this steel shop building as a tall, wide-open workshop in Hendricks County, west of Indianapolis. The owner's team bolted it together on site.
It is a cold-formed steel building from our M-Model line, with clear-span frames, Hawaiian Blue walls and a Galvalume roof, the system many customers choose for steel workshops and garages. Toro has supplied pre-engineered steel buildings for more than 40 years and sold more than 100,000 of them. Our in-house engineering team designs every building for the snow, wind and seismic loads at its site, and this steel shop building shipped with stamped drawings and calculations and was assembled locally by the owner's team.
Key takeaways
- Tall enough for real shop work. A 17 ft eave and a 3:12 roof leave room for lifts, tall equipment and overhead storage.
- Two 12 x 12 ft overhead doors on one endwall. Engineered with reinforced framing so both doors fit side by side on a 32 ft endwall.
- Built for Indiana weather. Designed to the 2012 IBC for 115 mph winds in open terrain and a 20 psf ground snow load, with 3 in. (R-10) insulation.
Steel shop building specs
The 32x56 steel shop building as ordered and engineered.
| Detail | Steel Shop Building: 32x56 Workshop |
|---|---|
| Location | Amo, Hendricks County, Indiana, USA |
| Building | Toro M-Model cold-formed steel building with clear-span frames |
| Size | 32 ft wide x 56 ft long |
| Eave height | 17 ft |
| Floor area | 1,792 sq ft, no interior columns |
| Roof | 3:12 gable, 26-gauge PBR panels in Galvalume |
| Walls | 26-gauge PBR panels in Hawaiian Blue, with white trim |
| Bays | Five bays, about 11 ft 2 in each |
| Framing | 14 in. 12-gauge cold-formed C-section columns and rafters with bolted brackets, knee braces and apex braces |
| Doors | Two 12 x 12 ft framed overhead door openings on the front endwall; walk door openings on the rear endwall and one sidewall |
| Insulation | 3 in. (R-10) faced insulation |
| Kit weight | About 12,600 lb, delivered as one complete package |
| Code | 2012 International Building Code (ASCE 7-10); cold-formed steel to AISI S100 |
| Ordered | September 2023 |
Price a building like this
Tell us your size, site and use, and a Toro building consultant will come back with an engineered, code-compliant quote.
Watch: from sealed drawings to the finished shop
This steel shop building went from sealed engineering drawings to a 3D design to the finished building in Amo. Watch the whole sequence, then see the build below.
This 32' x 56' x 17' cold-formed steel building in Amo, Indiana was engineered for 115 mph winds and Indiana snow, designed in 3D, and bolted together on site.
Read the video transcript
In Amo, Indiana, this shop had to be tall, wide open, and built to last. It started with sealed engineering: a 32 by 56 foot cold-formed steel building, stamped to the 2012 International Building Code for 115-mile-an-hour winds and Indiana snow. Then it came together in 3D: a 17-foot eave, a 3:12 roof, Hawaiian Blue walls, and two 12 by 12 overhead doors. The frames went up with bolts, not welding. Today, it's a clear-span workshop with room for anything. Design yours in 3D at torosteelbuildings.com.







Design your own building the same way with the free 3D building designer: set the width, length, height, doors, lean-tos, roof pitch, colours and wainscot, then send it to a building consultant for an engineered price.
Want a building like this one?
Send us your size, site and how you will use it, and a building consultant will come back with an engineered quote.
Engineered for Amo, Indiana: the design loads
Amo sits in Hendricks County, west of Indianapolis, in open farm country where wind matters as much as snow. These are the design criteria from this building's stamped calculations.
| Design criteria | Value |
|---|---|
| Building code | 2012 International Building Code (IBC) with ASCE 7-10 loads. Stamped drawings and calculations for the site |
| Cold-formed steel design | AISI S100, the North American specification for cold-formed steel structural members |
| Wind | 115 mph ultimate design wind speed, Exposure C (open terrain), risk category II |
| Ground snow load | 20 psf |
| Roof snow load (design) | 14 psf |
| Roof live load | 20 psf |
| Seismic | Ss = 0.188, site class D; low seismic design forces |
| Frames | 14 in. 12-gauge C-section columns and rafters, five bays at about 11 ft 2 in, knee and apex braces, X-bracing |
| Drawings supplied | Stamped calculations, stamped drawings, and the full construction package with framing, sheeting and anchor details |
See how we engineer every building on our engineering page, or read the 2012 International Building Code. More from Noah Sinclair, our in-house structural engineer.
Get loads engineered for your site
Every quote is engineered for the snow, wind and seismic loads where your building will stand.
Two 12 x 12 doors on one steel shop building endwall
Fitting two big doors on a 32 ft wide end takes engineering, not just openings.
The owner wanted to pull equipment straight in from the front, so this steel shop building has two 12 x 12 ft overhead doors side by side on its 32 ft endwall, with only a narrow strip of wall between them. That works because the endwall framing is designed around the openings:
- Endwall columns placed around the doors, so each opening has full-height framing on both sides.
- Heavier door jambs and headers that carry wind loads from the big doors back into the frames.
- A 17 ft eave, which leaves solid wall above each 12 ft door for bracing and trim.
- Walk doors kept separate, on the rear endwall and a sidewall, so people don't have to open a big door to get in.
Planning big doors? Tell your building consultant the door sizes before the design is finalized, because the framing is engineered around them. See our multi-door steel building kits.
Two 12 x 12 doors on a 32 ft endwall only work when the framing is designed around them.
Cold-formed frames, bolted together
Why this steel shop building went up without welding.
This is an M-Model cold-formed steel building. Its columns and rafters are roll-formed 14 in. C-sections, joined with bolted brackets at the haunches and the ridge. The photos show the result: the owner's team stood the frames up on the slab with a tractor, ladders and hand tools, then added girts, purlins and bracing before the panels went on.
- Precision-cut parts that arrive marked and ready to bolt together.
- Knee braces and apex braces that stiffen each frame without interior posts.
- X-bracing in the walls and roof that carries wind loads down to the anchors.
- About 12,600 lb for the whole kit, delivered as one package.
Construction with bolted cold-formed steel is typically 30 to 50% faster than conventional wood framing, because nothing is cut to fit on site.
No welding, no cutting to fit. The frames went up with bolts and hand tools.
Need a shop sooner?
New clearance buildings from orders that were never delivered often sell by phone before they are listed. Call to hear about unlisted inventory.
Insulation, colour and openings for a working shop
Built to be used every day, in every season.
- 3 in. (R-10) faced insulation under the panels, which keeps the shop more comfortable and reduces condensation. See how to insulate a steel building.
- Hawaiian Blue walls, a Galvalume roof and white trim, in 26-gauge PBR panels.
- A clear-span interior of 1,792 sq ft with no posts, so vehicles, lifts and benches can go anywhere.
- A 3:12 roof that sheds rain and snow and adds headroom down the middle of the shop.
What to watch for when you build a steel shop building in Indiana
Site, season and paperwork.
- Wind is the big load. Open farm country in central Indiana means Exposure C wind design, so give us the exact site address for your quote.
- Permits. In Amo and the rest of unincorporated and small-town Hendricks County, the Hendricks County Planning and Building Department issues the Improvement Location Permit. Bring your stamped drawings.
- Frost depth. Footings must go below the local frost line; your foundation designer uses the column reactions on the stamped drawings.
- Condensation. Humid summers and cold winters make insulation with a vapour retarder worth it in a heated or busy shop.
- Delivery. You unload the kit, so plan for a forklift or a tractor with forks and a clear path for the truck.
Building in Indiana?
Get a quote engineered for your site's wind and snow loads, within 1 business day.
What a steel shop building costs
How pricing works for a building like this one.
New Toro steel building kits start at $19 per sq ft (USD) in the United States and $26 per sq ft (CAD) in Canada, and every building is quoted to meet the loads and codes for your location and use. For a steel shop building like this one, the biggest price drivers are:
- the wind and snow loads at your exact site;
- eave height and roof pitch;
- the number and size of door openings;
- insulation and colour choices;
- delivery to your site.
Foundations, doors and assembly are separate costs, so budget for a local contractor or your own crew. See our steel building price guide and U.S. market trends.
Need a building sooner, or for less?
New, unused clearance buildings from orders that were never delivered are checked and engineered for your site like any Toro building.
Why Toro for a steel shop building
Engineering first, from the first call to delivery.
- In-house engineering. Every building is designed for its site's snow, wind and seismic loads, with stamped drawings for your permit.
- More than 40 years and more than 100,000 buildings sold, from garages to industrial plants.
- Precision laser-cut components that arrive ready to bolt together, so construction is typically 30 to 50% faster than conventional wood framing.
- Made in the USA for U.S. buildings, with a 25 to 40-year paint warranty on straight-wall buildings, depending on panel and finish.
- One building consultant from quote to delivery, with specialists who speak English, French, Spanish, Portuguese, Italian, Persian and Chinese.
Start your quote
Tell us your size, site and use, and get a free quote engineered for your loads and code.
How this building came together
Toro engineers and supplies the kit; the owner's team builds it.
Specification and 3D design
Toro and the ownerSize, eave, doors, insulation and colours set in the 3D designer.
Engineering
ToroThe steel shop building designed to the 2012 IBC for 115 mph winds and Indiana snow, with stamped drawings and calculations.
Permit and foundation
Owner or contractorImprovement Location Permit from Hendricks County; slab and anchors built to the stamped reactions.
Delivery
Toro ships, the owner unloadsThe complete kit, about 12,600 lb, delivered to Amo.
Assembly
Owner or contractorFrames, girts, purlins, insulation and panels bolted together on site. Toro doesn't install.
The building consultant who sold this building
Every Toro building has one consultant from first call to delivery.
Mary Wilson
Building Consultant · Toro Steel BuildingsMary Wilson sold this steel shop building and worked with the owner from the first design to delivery. She helps customers across the U.S. and Canada plan workshops, garages and storage buildings, including heavy-snow mountain sites.
More buildings Mary Wilson has sold
24x36x10, Sturgeon Bay WIA steel garage near Lake Michigan
20x30x14, Waterport NYA tall compact shop in western New York
35x40, Marion MTA steel building in northwest MontanaTalk to Mary about your building
Get an engineered quote for your size, site and loads, ask about new and unlisted clearance inventory, or see Mary's past projects.
Steel shop building FAQs
Still planning your build? Price your building and a building consultant will walk you through it.
How big is a 32x56 steel shop building?
A 32x56 steel shop building has 1,792 square feet of floor space. This one in Amo, Indiana has clear-span frames with no interior columns, a 17 ft eave and a 3:12 roof, enough for vehicles, a lift, workbenches and storage.
How much does a steel shop building cost?
New Toro steel building kits start at $19 per sq ft (USD) in the United States and $26 per sq ft (CAD) in Canada, and every building is quoted to meet the loads and codes for your location and use. Wind and snow loads, eave height, door openings, insulation and delivery have the biggest effect on the final price.
What wind and snow loads is a steel shop in Amo, Indiana designed for?
This building was designed to the 2012 International Building Code for a 115 mph wind speed in Exposure C (open terrain), a 20 psf ground snow load and a 14 psf design roof snow load. Every Toro quote uses your exact site.
Can a steel shop building have two 12 x 12 overhead doors on one end?
Yes, when the endwall framing is engineered around them. This 32 ft wide building has two 12 x 12 ft overhead door openings side by side, with columns and jambs placed for both doors and a 17 ft eave above them.
Do I need a permit for a steel shop building in Hendricks County, Indiana?
Yes. In Amo and much of Hendricks County, the Hendricks County Planning and Building Department issues the Improvement Location Permit. Every Toro building comes with stamped drawings and calculations, which is what the building department asks for.
What foundation does a steel shop building need?
Usually a concrete slab with thickened edges or footings below the frost line, designed locally for your soil using the column reactions on the stamped drawings. Toro doesn't build foundations, but supplies everything your contractor needs to design one.
How long does it take to build a steel shop building?
Delivery of a Toro building kit usually takes 2 to 8 weeks, and your building specialist confirms timing. The components arrive precision-cut and ready to bolt together, so construction is typically 30 to 50% faster than conventional wood framing.
Can a steel shop building be insulated?
Yes. This one has 3 in. (R-10) faced insulation. Insulation is an option on any Toro kit, and in Indiana's humid summers and cold winters it also helps prevent condensation.
Keep reading
Related building types
Steel workshops | Steel garages | Storage buildings | Commercial steel buildings | Cold-formed steel buildings
Planning a shop like this?
Toro Steel Buildings engineers your kit for your site's wind, snow and seismic loads, with a quote within 1 business day.